Quick summary
Upstream emissions are Scope 3 emissions from activities linked to what your company buys, uses and leases, from purchased goods and capital equipment to energy, transport, business travel and employee commuting. To measure them:
- Screen all eight categories: Run a quick spend-based estimate to see which ones carry the most weight for your business.
- Start with purchased goods and capital goods: Move your biggest spend lines toward supplier data first.
- Work through energy, transport, travel, and waste: Each has its own data source and method, from fuel bills to tonne-kilometers.
- Check the results, then act: Compare year over year, fix errors, and test reduction options before you commit.
Why upstream emissions decide your footprint
Chances are, most of your emissions don’t come from anything you own or run. In 2023, companies reporting to CDP said their supply chain emissions were on average 26 times higher than their own operations.
That’s a hard number to ignore. And your customers aren’t ignoring it either, because the emissions in the products you sell end up in their Scope 3. So we hear more buyers asking suppliers for product-level carbon data, sometimes right in the tender. Regulation adds pressure too, but the customer question tends to come first.
So which categories count as upstream, where does the data come from, and how accurate does it need to be?
Why Listen to Us?
At Polarn O. Pyret, store managers report and check their own store’s data in Emission Twin, and one or two superusers per region set the deadlines. Getting the data straight from the source improved its quality and cut out double work. That’s how the team “went from chasing numbers, to driving change.”

Lejonfastigheter uses us as a central hub and a quality check on its emission factors. The team also likes knowing a third party can review its numbers. And upstream accounting depends on that combination, data from the people closest to it and emission factors you can trace.
What Are Upstream Emissions?
Upstream emissions are the indirect greenhouse gas emissions tied to the goods and services a company buys. They cover everything that happens before those purchases reach you, from mining the raw materials to trucking finished parts to your door.
Downstream emissions are the other half, and they come from the products you sell.
Both halves are part of Scope 3, which covers the indirect emissions in your value chain that aren’t already counted in Scope 2. As a quick reminder, Scope 1 is the fuel you burn and the processes you run yourself. Scope 2 is the electricity, heat, and steam you buy. The GHG Protocol splits Scope 3 into 15 categories, with 1 to 8 upstream and 9 to 15 downstream.
The table below maps each upstream category to what it covers and the data you’ll need. The methods come from the GHG Protocol’s Technical Guidance for Calculating Scope 3 Emissions.
| Scope 3 category | What it covers | Data you’ll need | Calculation methods |
| 1. Purchased goods and services | Cradle-to-gate emissions of the goods and services you buy that aren’t in Categories 2 to 8 | Spend by supplier, quantities by material, supplier product footprints | Supplier-specific, hybrid, average-data, spend-based |
| 2. Capital goods | Cradle-to-gate emissions of machinery, buildings, vehicles, and other long-life assets you buy | Capital spend, asset types and quantities | The same four methods as Category 1 |
| 3. Fuel- and energy-related activities | Producing and transporting the fuel and electricity you use, plus grid transmission and distribution losses | Your Scope 1 fuel use and Scope 2 electricity use | Supplier-specific, average-data |
| 4. Upstream transportation and distribution | Transport from your tier 1 suppliers, plus any transport and storage you pay for, including deliveries to customers | Weights, distances, transport modes, freight spend | Fuel-based, distance-based, spend-based |
| 5. Waste generated in operations | Treating and disposing of your waste in facilities you don’t own or control | Waste weight by type and treatment method | Supplier-specific, waste-type-specific, average-data |
| 6. Business travel | Work trips in vehicles you don’t own or operate, with hotel stays optional | Distance or fuel by travel mode, travel spend | Fuel-based, distance-based, spend-based |
| 7. Employee commuting | Staff travel between home and work, with teleworking optional | Commuting survey answers, distances, working days | Fuel-based, distance-based, average-data |
| 8. Upstream leased assets | Running the assets you lease that aren’t already in your Scope 1 or 2 | Energy use or floor area of leased assets | Asset-specific, lessor-specific, average-data |
In oil and gas, “upstream” means something different, the exploration and production side of the business. The closest overlap in corporate accounting is Category 3, which counts the emissions from producing the fuel and power you use.
How to Measure Upstream Emissions
1. Screen all eight categories before you collect anything
You can’t perfect every category at once, and honestly, you don’t need to. The GHG Protocol does ask you to account for all Scope 3 emissions and to justify anything you leave out. But it also gives you relevance criteria, like size, influence, and risk, to help you decide where to focus.
The quickest way to see which categories are big is a spend-based first pass. Pull a year of purchasing data from your finance system and group it by what you bought. Then multiply each group by an environmentally extended input-output (EEIO) factor, which is the average emissions per dollar or euro spent in a sector. The US EPA publishes a free set of factors made for this kind of estimate.
The result will be rough, and that’s fine, because you’re only looking for the categories that clearly matter. While you’re at it, take three more steps:
- Rank the categories by estimated tonnes, then flag any where you have influence, like a supplier that provides most of your steel.
- Note what data exists today and who holds it, whether that’s procurement, logistics, HR, or facilities.
- Write down every exclusion with a reason, because auditors and customers will ask about it.
Your screen also matters for two sets of rules. The first is the revised European Sustainability Reporting Standards (ESRS). If you’re in scope, you’ll need to screen all 15 categories, then pick out the significant ones by size, spend, and influence.
The second is the Science Based Targets initiative (SBTi). Under its current near-term criteria, if Scope 3 represents more than 40% of your total Scope 1, 2 and 3 emissions, your targets must cover at least 67% of your Scope 3 emissions.
2. Measure purchased goods and capital goods (Categories 1 and 2)
Purchased goods and services covers the cradle-to-gate emissions of every material, component, and service you buy. Cradle-to-gate means everything from extracting the raw materials to the moment a product leaves your supplier’s gate. And it’s a big one. In a University of Cambridge analysis of CDP data, Categories 1 and 11 together made up 84% of reported Scope 3 emissions. (Category 11, the use of sold products, is downstream.)
Capital goods uses the same four methods, so it’s worth tackling the two together. From the roughest to the most specific, they are:
- Spend-based: Multiply what you spent by an EEIO factor per unit of money. It’s quick, but because the factor is a sector average, a supplier who cuts its emissions won’t show up in your number.
- Average-data: Multiply the mass or quantity you bought by an average emission factor per kilogram or unit from a published database.
- Hybrid: Use supplier data where you’ve got it and fill the gaps with secondary data like industry averages.
- Supplier-specific: Use the cradle-to-gate footprints your suppliers calculate for the exact products you buy.
Start with your biggest spend lines, and work your way down that list toward supplier-specific data. There’s one catch, though. The GHG Protocol’s own guidance notes that supplier data can sometimes be less accurate than industry averages. So ask how a supplier calculated its number before you swap it in.
This is also where product data and company-wide data come together. A product carbon footprint (PCF) is the emissions tied to a single product. A supplier’s cradle-to-gate PCF is exactly the supplier-specific input Category 1 asks for. So the same product-level data your customers want from you can fill your own inventory, once you collect it from your suppliers.
Emission Twin is a climate intelligence and management platform built on a digital twin architecture. Our Scope 3 coverage includes every GHG Protocol category.
In Emission Control, you can send data requests with deadlines to suppliers and colleagues, then track who’s responded. You can also mix spend-based and activity-based calculations in one inventory. And you can switch a category from spend to activity data between years yourself, at no extra cost.

Our matching system suggests an emission factor for each activity, and each one shows its source reference. That way, you or your climate consultant can check it before it counts.
Kid/Hemtex is now getting ready to move its Scope 3 from generic assumptions to actual supplier data, with source files linked to its data points. We’re also working on linking product footprints and the corporate footprint at the data level. That way, product data you collect once can feed Category 1 directly.
3. Calculate fuel- and energy-related activities (Category 3)
Category 3 counts the emissions from producing the fuel and electricity you’ve already reported in Scopes 1 and 2. That covers extracting, refining, and transporting fuels. It also covers the power that’s lost in the grid on its way to you, known as transmission and distribution losses.
Luckily, you don’t need any new data for this one. Take your Scope 1 fuel use and Scope 2 electricity use, then apply upstream emission factors. For fuels, the GHG Protocol defines the upstream factor as the life cycle emission factor minus the combustion factor. You’ll find them listed as well-to-tank (WTT) factors in the UK government’s 2026 greenhouse gas conversion factors. That set also has factors for transmission and distribution losses.
Just be careful not to double count. Your Scope 2 figure already includes the fuel burned at the power plant to make your electricity. So Category 3 only adds the steps before that, plus the grid losses. There’s one more Category 3 activity, generating electricity that’s resold to end users, but it only applies to utilities and energy retailers.
4. Measure upstream transportation and distribution (Category 4)
Category 4 covers two kinds of transport. The first is anything shipped to you by your tier 1 suppliers, the ones you buy from directly, in vehicles you don’t own. The second is any transport and storage you pay for, including deliveries to customers and trips between your own facilities.
The category depends on who pays for the trip. If you’re paying a carrier to deliver your products, that transport belongs in Category 4, even if the goods are heading to your customer. If the transport happens after the point of sale and isn’t purchased by your company, it falls under Category 9.
You’ve got three methods for the transport itself:
- Fuel-based: Use the fuel your carriers burned on your shipments, when they can share it.
- Distance-based: Multiply the mass shipped by the distance of each leg and a factor for the transport mode.
- Spend-based: Multiply your freight spend by an EEIO factor, which is fine for a first pass.
For example, if you ship 20 tonnes of components 500 km by truck, that’s 10,000 tonne-kilometers. Then you multiply that by a road freight factor per tonne-kilometer from your chosen database. You’d repeat that for every leg and mode, since one shipment might go by sea, then rail, then truck.
You’ll usually find the weights and routes on your freight invoices and carrier reports. Any warehouses you pay for get their own site-specific or average-data estimate.
5. Estimate business travel and employee commuting (Categories 6 and 7)
Business travel covers work trips in vehicles you don’t own or operate, like flights, trains, rental cars, and taxis. Your travel agency or booking tool can usually export trips by distance and mode, which is what the distance-based method needs. Spend-based works as a fallback, and hotel stays are optional to include. Cars your company owns belong in Scope 1, so leave them out here.
Employee commuting counts the trips your staff make between home and work. The GHG Protocol’s distance formula is the one-way distance, times two, times the number of commuting days. So an employee who drives 12 km each way on 220 working days covers 5,280 km a year. Then you multiply that by a factor for their type of car.
You probably won’t have that data on file, so a short survey is the easiest way to get it. Ask how people commute, how far, and how many days they’re in the office. If you can’t reach everyone, survey a representative sample and scale it up. Teleworking emissions, like the energy used to heat home offices, are optional here too.
6. Cover waste and upstream leased assets (Categories 5 and 8)
Waste generated in operations counts the emissions from treating and disposing of your waste in facilities you don’t own or control. You’ll need the weight of each waste type and how it’s treated, like landfill, incineration, or recycling. Your waste contractor’s invoices or reports tend to list both, and that’s what the waste-type-specific method needs. Including the transport of the waste is optional.
Upstream leased assets covers running the buildings, vehicles, or equipment you lease. It only applies when those emissions aren’t already in your Scope 1 or 2. Check your existing inventory first so you don’t count the same leased office twice. If you’ve got meters, their readings give you an asset-specific figure. If you don’t, floor area times an average energy intensity works.
If your screen showed these two categories as small, a reasonable estimate with a documented method is enough. Your time is better spent on Category 1.
7. Check the results and test your reduction options
Numbers built from dozens of sources will have errors, so you’ll want to check them before anyone quotes them. Compare each category year over year, and dig into any jump. A spike in Category 4 might mean you shipped more, or it might be a unit mistake, like kilograms entered as tonnes. Grouping results by emission factor helps too, since it shows when a factor update caused the change.
In Emission Twin, the comparison tool starts at the category level and drills down to single activities, or groups results by emission factor.
Once you trust the numbers, Reduction Roadmap recalculates your inventory with industry-specific actions, like switching to recycled materials. It measures each one against your base year and target, so you see the emissions effect of each action before you commit. Cost, quality, and feasibility are still decisions your team makes, but the simulation gives you a number to work from.

That’s exactly what happened at Bubbleroom.

When the team simulated using more recycled materials in its products, it turned out the effect on the overall footprint was relatively low. So it became clear to the whole management team that they needed other initiatives to reach their climate goals. And that’s a much cheaper lesson to learn in a simulation than after the switch.
Start with the categories that carry your footprint
Upstream emissions can feel like one enormous number until you split them into eight categories. Once you do, each one’s just a data source and a method. Screen them all, then put your effort into purchased goods and the other categories that matter most for your business. From there, improve the data step by step.
Want to see how that works with your own data, from supplier requests to traceable factors and simulations? Book a demo with Emission Twin, and we’ll walk you through it in Swedish or English.
FAQs
What’s the difference between upstream and downstream emissions?
Upstream emissions come from the goods and services your company buys, up to the point you receive them. Downstream emissions come from the products you sell, including transporting them, how customers use them, and what happens when they’re thrown away.
Is it mandatory to report upstream Scope 3 emissions?
For companies within the revised EU sustainability reporting scope, yes. Under Directive (EU) 2026/470, the CSRD scope from financial years starting on or after 1 January 2027 covers undertakings exceeding both €450 million in net turnover and an average of 1,000 employees. The revised ESRS requires companies to screen their Scope 3 emissions across the 15 GHG Protocol categories, identify the significant categories, and report gross Scope 3 emissions in accordance with the applicable requirements.
Are upstream emissions the same as cradle-to-gate emissions?
Partly. They overlap for Categories 1 and 2, where the GHG Protocol sets cradle-to-gate as the minimum boundary for the goods you buy. But upstream emissions also include categories that aren’t part of any product’s footprint, like business travel, employee commuting, waste, and leased assets. So cradle-to-gate is about one product’s history, and upstream is about your whole company’s purchasing.
How accurate do upstream emissions need to be?
Accurate enough to guide decisions in the categories that matter, and traceable everywhere. Spend-based estimates are fine for screening and small categories. But where emissions are large or you’re planning reductions, aim for supplier-specific or activity data, because averages can’t show your progress. Document every factor and source so a reviewer can follow the math.